Sign In | Join Free | My burrillandco.com
Home > Power Module >

ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module

Changsha Xingheda Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
     
    Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
    • Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
    • Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
    • Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
    • Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers
    • Buy cheap ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module from wholesalers

    ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module

    Ask Lasest Price
    Brand Name : ELTEK
    Model Number : Flatpack S 24V/1000W HE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 500pcs/week
    Delivery Time : 3-7 work days
    • Product Details
    • Company Profile

    ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module

    ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module


    Product Description:

    ELTEK Flatpack S 24V/1000W HE 241122.205 rectifier module is used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.


    Model24/1000 HE
    Part number241122.205
    INPUT DATA
    Voltage (nominal range)185 VAC/DC - 305 VAC / 300VDC
    Voltage (operating range)85 VAC/DC - 305 VAC / 300VDC
    Frequency (nominal / range)45 - 66 Hz / DC
    Maximum current5.9 ARMS
    Power Factor> 0.99 at 50% load or more
    Protection

    Fuse

    Shutdown above 305 VAC / 300 VDC

    OUTPUT DATA
    Voltage (default)26.7 VDC
    Voltage (adjustable range)

    21 - 29 VD 1)

    C

    Max power, nominal input1000 W
    Max power, @ 85 VAC/DC440 W
    Max current41.7 A (@VOUT < 24 VDC)
    Current sharing±5% of maximum current from 10 to 100% load
    Static voltage regulation (10-100% load)±0.5%
    Dynamic voltage regulation±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
    Hold up time>20ms; output voltage > 21 VDC
    Ripple< 150 mVPP , 30 MHz bandwidth

    Protection

    Blocking OR-ing Diode, Short circuit proof, Over voltage protection and High temperature protection
    OTHER SPECIFICATIONS
    Peak Efficiency92.5 %
    Isolation3.0 kVAC - input and output, 1.5 kVAC - input earth, 0.5 kVDC - output earth
    Alarms (Red LED)Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure
    Warnings (Yellow LED)Rectifier in power de-rate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage
    Normal (Green LED)Input and output ok
    Potential alarm relay (normally closed)Opens on alarms and mains outage
    MTBF (Telcordia SR-232 Iss.3 Meth. II Case L1)>1 975 044 (@ Tambient : 25 °C)
    Operating temperature (5 - 95% RH non-cond.)- 40 - 85°C [-40 - 185°F ]
    Max output power de-rates above temp / to45°C [+113°F] / 400 W
    Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
    Dimensions[WxHxD] / Weight72 x 41.5 x 217mm (2.83 x 1.63 x 8.54”) / < 850 g (1.9 lbs)
    DESIGN STANDARDS
    Electrical safety

    EN 62368-1:2020+A11:2020, IEC 62368-1:2018, UL 62368-1:2019

    IEC 60950-1:2013


    EMC

    EN 61000-6-1:2019, -6-2:2019, -6-3:2007 + A1:2011, -6-4:2019

    IEC 61000-6-5:2015, FCC CFR 47 Part 15:2013

    ETSI EN 300 386v2.2.0, EN50121-4:2016 + A1:2019, -5:2017 + A1:2019

    MarineDNVGL-CG-0339, ABS PDA Certificate2)

    Environment

    ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

    EU 2015/863 (RoHS), 2012/19/EU (WEEE), IEC 63000:2018

    Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised


    Product Details:


    If you are interested, please let us know the specific model. We will provide the best service and the best price!

    Pr

    Quality ELTEK Flatpack S 24V/1000W HE 241122.205 Rectifier Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changsha Xingheda Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)